内页图
Search
Home Search
1 results found for "vfd centrifuges machine"
  • 75kW-220kW Universal VFD
    75kW-220kW V6 Series High Performance Universal Inverter
    Product Overview Item Description Product Name Frequency Inverter/ AC Drive Model Number V6-H-4TxxG/xxL Power Range 0.75kW-500kW Rated Input Voltage 3 phase 380V/480V Rated Output Voltage 3 phase 0 to rated input voltage Input Frequency 50Hz/60Hz Adaptable Motor Asynchronous Motor Control Mode V/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control, Vector Torque Control Communication Modbus 485 RTU IP Class Standard IP20 Overload Capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) Feature ■ Open - loop vector, Closed - loop vector, Open - loop torque, Closed - loop torque control. ■ Inverter operates stably without tripping under any acceleration and deceleration time and any impact load. ■ Real torque control is realized through the independent current loop control, and online switching between torque control and speed control is supported. ■ Independent input and output port of high speed pulse, which can realize high speed pulse cascade function. ■ Accurate speed identification and rotor flux orientation, the torque can also respond quickly and operate stably when a load of 0.25hz breaks. ■ High-precision current detection and protection, high-precision hall to detect output current, realization of fast real-time control and protection of software and hardware, and assurance of performance and reliability of the whole machine. Model Explanation Product Catalogue V6−H−4T□□□G ;Three−phase 400V Constant torque/heavy−duty application Power (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Motor power (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Output Voltage (V) Three-phase 0 to rated input voltage Rated current (A) 2.5 3.8 5.5 9 13 17 24 30 39 45 60 75 91 112 150 Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag ;feature) Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz Allowable voltage range 323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5% Rated current (A) 2.8 4.2 6.1 10 15 19 26 33 43 50 66 83 100 123 165 Braking unit Built-in as standard Built-in as option Protection class IP20 Cooling mode Natural−cooling Forced air cooling Power (kW) 90 110 132 160 185 200 220 250 280 315 355 400 450 500 Motor power (kW) 90 110 132 160 185 200 220 250 280 315 355 400 450 500 Output Voltage (V) Three-phase 0 to rated input voltage Rated current (A) 176 210 253 304 350 380 426 470 520 600 650 690 775 860 Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag ;feature) Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz Allowable voltage range 323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5% Rated current (A) 160* 196* 232* 282* 326* 352* 385* 437* 491* 580* 624* 670* 755* 840* Braking unit External braking unit needed Protection class IP20 Cooling mode Forced air cooling *V6−H−4T90G and higher products are equipped with external DC reactor as standard. V6−H−4T□□□L ;Three−phase 400V Variable torque/light−duty application Power (kW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 Motor power (kW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 Output Voltage (V) Three-phase 0 to rated input voltage Rated current (A) 3.3 5 7.5 11 17 22 30 37 44 56 72 91 110 142 176 Overload capacity 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz Allowable voltage fluctuation range 323V ~ 528V; Voltage imbalance: ≤3%; allowable frequency fluctuation: ±5% Rated current (A) 3.6 5.5 8.3 12 19 25 33 40 50 62 80 100 121 156 194 Braking unit Built-in as standard Built-in is optional Protection class IP20 Cooling mode Natural cooling Forced air cooling Power (kW) 110 132 160 185 200 220 250 280 315 355 400 450 500 560 Motor power (kW) 110 132 160 185 200 220 250 280 315 355 400 450 500 560 Output Voltage (V) Three-phase 0 to rated input voltage Rated current (A) 210 253 304 350 380 426 470 520 600 650 690 775 860 950 Overload capacity 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz Allowable voltage range 323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5% Rated current (A) 196* 232* 282* 326* 352* 385* 437* 491* 580* 624* 670* 755* 840* 920* Braking unit External braking unit needed Protection class IP20 Cooling mode Forced air convection cooling *V6−H−4T110L and ;higher power ;products are equipped with external DC reactor as standard. V6−H−2T□□□G Three−phase 200V Constant torque/heavy−duty ;application Power (kW) 0.4 0.75 1.5 2.2 Motor power (kW) 0.4 0.75 1.5 2.2 Output Voltage (V) Three−phase 0 to rated input voltage Rated current (A) 3 5 7.5 10 Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interva...
    A total of

    1

    pages

Categories

Copyright © 2021 Shenzhen V&T Technologies Co.,Ltd. All Rights Reserved. Power by

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #