Textile Inverter for spinning machine

V5−BA series is a high-performance vector control inverter launched by V&T for spinning frame in textile industry. The product adopts the open-loop vector control technology with the current international advanced technology, which has the same excellent control performance with the international high-end inverter.

  • Sample provide:

    YES
  • Sample freight payer:

    Buyer
  • Term of payment:

    T/T, L/C, D/P
  • Customized:

    YES
  • Warranty:

    18 Months
  • Delivery Time:

    5-7 working days for standard series; 7-14 working days for customized AC drives
  • Transportation:

    Express · Sea freight · Land freight · Air freight
  • Package:

    Standard Export Package Carton/Wood
  • Availability:

    OEM/ODM, Minmum Order Request
  • Place of Origin:

    China
  • Shipping Port:

    Shenzhen
  • Certification:

    CE, EAC, ISO9001, OHSAS18001, TS16949, SGS
  • Product Detail

Product Overview

Product Name Frequency Inverter/ AC Drive
Model Number V5-BA-4Txx
Power Range 7.5kW-90kW
Rated Input Voltage 3 phase 380V/480V
Rated Output Voltage 3 phase 0 to rated input voltage
Input Frequency 50Hz/60Hz
Control Mode V/F Control, Vector Control, Sensorless Vector Control, Vector Torque Control
IP Class Standard IP20
Overload Capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)


Feature

■ Designed for requirements of spinning frames in textile machinery ;with convenient installation outside ;cabinet;

■ Suitable for dusty industrial sites, ;and ;the radiator is easy to clean;

■ After the inverter temperature exceeds the set value, ;it ;reminds ;the user to clean the radiator and fan;

■ Easy to operate, single button to stop, ;being zero ;on full yarn and wire break;

■ Built-in swing frequency function can output triangle frequency and kick frequency to prevent yarn overlap and facilitate unwinding;

Stop automatically to avoid wire break ;after the pulse feedback signal ;misses;


Model Explanation


Product Catalog

V5−BA−4T□□□ ; ; ;

Power (kW)

7.5

11

15

18.5

22

30

37

45

55

75

90

Adapter motor power (kW)

7.5

11

15

18.5

22

30

37

45

55

75

90

Output

Voltage (V)

3-phase 0 to rated input voltage

Rated current (A)

17

22

30

37

44

56

72

91

110

142

176

Overload capability

115% 1 minute, 160% 0.5 seconds, interval 10 minutes (inverse time characteristic)

Input

Rated voltage / frequency

3-phase 380V/480V; 50Hz/60Hz

Allowable voltage range

323V ~ 528V; voltage imbalance: 3%; allow frequency fluctuation: ± 5%

Rated current (A)

19

26

33

41

48

62

79

100

121

156

194

Brake unit

Built-in as standard

Built-in as optional

IP

IP20

cooling method

Forced air cooling


Technical Parameters

control method

Open loop vector control

Power range

7.5kW~90kW

Input voltage, frequency

3AC 380V~480V;50Hz/60Hz

The output voltage

3AC 0 ~ rated input voltage

Output frequency

0.00~300.00Hz; vector control 1 operation mode 0.0~3000.0Hz can be customized according to customer needs

Digital input and output

Standard multi-function input terminal, expandable

Standard open collector output, expandable

Analog input and output

Input: AI1 0~20 mA, input impedance 500Ω, maximum input current 30mA;

0~10V, input impedance 20kΩ, maximum input voltage 15V, resolution 12 bits (0.025%)

Select 0 to 20 mA or 0 to 10V analog input by jumper


AI2 Same as above

; ; ; ; ; ;

AI3 −10V~10V, input impedance 20kΩ maximum input voltage ±15V, resolution 12 bits (0.025%)

Output: AO1 0~20 mA, output allowable impedance 200~500Ω

; ; ; ; ; ; ; ; ; ; ;0 to 10V, output allowable impedance ≥10kΩ, resolution is 10 bits (0.1%)

Short-circuit protection function, select 0~20 mA or 0~10V analog output by jumper


AO2 Same as above

Pulse input and output

Pulse input: 0.1Hz ~ 50kHz; voltage range: 24V ± 20%

Pulse output: 0 ~ 50kHz; voltage range: 24V ± 20%

Protocol

Dual 485 communication interface supports Modbus protocol (RTU), standard operation panel can realize remote control , up to 500 meters


Brake unit

15kW and below power section models are built-in;

18.5kKW ~ 90kW power section built-in optional

External interface

DC24V ;power source,maximum input current ;100 ;mA

fan

The standard machine does not have a fan. If you need to add a fan, you can add "−57" to the back of the model.

DC reactor

Need to be external

Installation method

Wall mounting

IP

IP20


Model table

Voltage

Model

Three-phase 400V variable torque / light load application

Motor (kW)

Rated output current (A)

Rated input current (A)

400V

V5−BA−4T7.5

7.5

17

27.9

V5−BA−4T11

11

24

39

V5−BA−4T15

15

30

50.3

V5−BA−4T18.5

18.5

37

60

V5−BA−4T22

22

44

69.3

V5−BA−4T30

30

56

86

V5−BA−4T37

37

72

104

V5−BA−4T45

45

91

124

V5−BA−4T55

55

110

150

V5−BA−4T75

75

142

190

V5−BA−4T90

90

176

235


Installation Dimension



V5−BA ;Outline and installation dimensions ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;V5−BA−57 ;Outline and installation dimensions





V5−BA series Outline and installation dimensions and approximate weight



Voltage

Model

Outline and installation dimensions (mm)

weight (kg)

W

H

D

W1

H1

D1

W2

Hole d

V5−BA−4T7.5

206

303

153

166

251

96

136

8

6.5

V5−BA−4T11

V5−BA−4T15

236

386

201

236

318

102

170

8

9.5

V5−BA−4T18.5

V5−BA−4T22

345

483

238

295

410

130

220

8

18

V5−BA−4T30

V5−BA−4T37

V5−BA−4T45

400

610

297

340

520

183

260

10

30

V5−BA−4T55

V5−BA−4T75

470

639

302

410

545

183

320

10

40

V5−BA−4T90


V5−BA−57 series Outline and installation dimensions and approximate weight


Voltage

Model

Outline and installation dimensions (mm)

weight (kg)

W

H

D

W1

H1

D1

W2

Hole d

V5−BA−4T7.557

206

303

185

166

251

96

136

8

7.5

V5−BA−4T1157

V5−BA−4T15−57

286

386

245

226

308

102

170

8

10.5

V5−BA−4T18.5−57

V5−BA−4T22−57

345

482

286

285

400

130

220

8

19

V5−BA−4T30−57

V5−BA−4T37−57

V5−BA−4T45−57

400

610

343

330

520

183

260

10

31

V5−BA−4T55−57

V5−BA−4T75−57

470

639

350

400

545

183

320

10

41

V5−BA−4T90−57


Option / Expansion Card

category

name

model

Function Description

reference

Operation panel

Operation panel (shuttle ;type)

V6DP01

Full range of models

P2−**

Operation panel (button type)

V6DP02

Full range of models

P2−**

Text display

EXMT01

Man-machine interface - text display

P2−**

touch screen

EXMT02

Human-machine interface - touch screen

P2−**

Fake panel

V6DP03

Customer option

P2−**

Pallet

V6DP05

Operation panel mounting accessories

P2−**

Expansion Card

Power monitoring card

EXPA01

Three-phase input power supply phase loss / instantaneous power failure monitoring

P2−**

Phase detection card

EXPA02

Three-phase input power phase detection

P2−**

External power rectifier card

EXRF01

Control power is provided by external power supply

P2−**

Programmable CAN bus expansion card

EXCA05

;

P2−**

Profibus DP communi

;

;

;

;

;

;

;

cation card

EXCA06

;

P2−**

Keyboard extension cord

2 m keyboard extension cable

CB1200

;

P2−**

3 m keyboard extension cable

CB1300

;

P2−**



Applications











Representative Industry

The textile spinning frame can also be used in other industries where dust is frequently cleaned.



Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Categories

Related Products
Inverter Operation Panel
V6-DP02 Key Type Operation Panel

Key Type Operation Panel

Multiple function VFD
0.75kW-2.2kW VTS Series Universal Variable Speed AC Drive

Adopting brand-new vector control technology, VTS series inverter can be compatible with the control of synchronous motor, asynchronous motor and reluctance motor, as well as the encoders with multiple specification and abundant communication interface and support English liquid crystal display, five-digit digital pipe display operation panel; and with the protection functions of usability, extendbility, small volume, light weight and perfection, VTS series inverter can meet the medium-high application demands.

Universal Inverter VFD
3.7kW-15kW V5 Series High Performance Universal Inverter

V5-H series is a high-performance vector control inverter. The product adopts open-loop vector control technology ;which is completely synchronized with the most advanced technology in the world. It has the excellent control performance with the international high-end frequency converter.

250kW-500kW Sensorless Vector Control VFD
250kW-500kW V5 Series High Performance Universal Inverter

V5-H series is a high-performance vector control inverter. The product adopts open-loop vector control technology ;which is completely synchronized with the most advanced technology in the world. It has the excellent control performance with the international high-end frequency converter.

Motor Controller for Electrical Truck
Motor controller for Electrical Truck Van pickup truck Light truck Heavy truck

Meet various vehicles applications By the end of June 2018, more than 200,000 units/sets have been used in various vehicle types: ■ Passenger vehicle (bus/commuter): small sea lion, Coster, 8.5m-12m passenger bus, 18m dual source trolleybus ■ Trucks: mini van and mini truck under 2.5 tons, 3.5-7.5 tons light trucks, 18-55 tons heavy trucks ■ Special-Purposed vehicles: sanitation truck, sprinkler truck, dust suppression truck, dock tractor, tunnel engineering tractor ■ Passenger car: A-class sedan, SUV

75kW-220kW Inverter
75kW-220kW V9 Series High Performance Universal Speed AC Drive

V9−H Series General Purpose Inverter is a high-performance vector control and torque controlled inverter. Vector control technology and torque control technology are employed. It can better meet the needs of various transmission applications.Voltage range covers 200V, 400V, 690V, and 1140V. The product power range covers 0.4kW to 3MW.

Sensor Vector Inverter
3.7kW-15kW V6 Series High Performance Universal Inverter

V6-H series is a high performance vector control and torque control inverter.The product adopts close-loop vector control technology and torque control technology which are synchronized with the current international advanced technology, and it has the same excellent control performance with the international high-end frequency converter.

0.75kW-2.2kW Universal Speed AC Drive
0.75kW-2.2kW V9 Series High Performance Universal Speed AC Drive

V9−H Series General Purpose Inverter is a high-performance vector control and torque controlled inverter. Vector control technology and torque control technology are employed. It can better meet the needs of various transmission applications.Voltage range covers 200V, 400V, 690V, and 1140V. The product power range covers 0.4kW to 3MW.

Copyright © 2021 Shenzhen V&T Technologies Co.,Ltd. All Rights Reserved. Power by

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #
  • #
    Refresh the image