Product introduction

Product Features
Adapts the voltage 220V, 380V, 460V, 660V all brand frequency converter, the single machine power reaches 400KW;
Digital control, complete current sharing from parallel within 8 units;
High power with LED keyboard control, more convenient operation;
Three specifications of the same power are available, with a wide range of product lines to meet customers with different cost-effectiveness requirements;
Protection function, strong anti-interference function, and high reliability.

Brake Unit Model and Specification

ModelRecommended ResistanceRated CurrentMaximum CurrentOperating VoltageSetting MethodParallel Function
Economical Type
VT-DR-1L33Ω6A33A620, 640, 680, 720; Default: 640VModified by the main control board jumper pin base S1NO
VTBU4030G20Ω9A75A
VTBU4055G13.6Ω12A100A
General Type
VTBU4030H 20Ω10A75A620, 640, 680, 720; Default: 680VModified by the main control board jumper pin base S1YES
VTBU4055H13.6Ω15A100A
VTBU4075H9.1Ω25A150A
VTBU4030N20Ω10A75AYES
VTBU4055N13.6Ω15A100A
VTBU4075N9.1Ω25A150A
VTBU4090N7.5Ω30A150AQ580, 610, 640, 670, 700, 730; Default: 670V
VTBU4110B5.6Ω70A150A
VTBU4220B4.0Ω85A200A
VTBU4315B2.8Ω120A300A
VTBU4400B2.0Ω160A450A
High-end Type
VTBU4110H5.6Ω70A150A610, 615, 625, 635, 645 ,655, 675, 685 ,695; Default: 675VSet by the operation panel, see section 4.5 for the operation methodYES
VTBU4210H4.0Ω85A200A
VTBU4315H2.8Ω120A300A
VTBU4400H2.0Ω160A450A
VTB4110N5.6Ω70A150A580, 610, 640, 670, 700, 730; Default: 670VModified by the main control board jumper pin base S1YES
VTB4220N4.0Ω85A200A
VTB4315N2.8Ω120A300A
VTB4400N2.0Ω160A450A
VTB6110N10Ω70A150A1010, 1050, 1090, 1130, 1170, 1190; Default: 1130V
VTB6220N7.5Ω85A200A
VTB6315N5.0Ω120A300A
VTB6400N3.5Ω160A400A

Technical Parameters

Item Specification
Power SupplyPower Voltage3AC 220V, 380V, 460V, 660V±10%
Power Network Frequency50Hz±5Hz
Control SystemBraking DeviceDynamic voltage tracking
Response Time≤1ms
  
Hysteresis Voltage≤10V
Current ProtectionOver-pressure and over-temperature (over 85°C-RRB-protection)
Fault OutputRelay contact output: capacity AC250V/3A
DisplayStatus DisplayPower supply voltage, operating state, fault state (high-end H-type)
Operation DisplayOperation Indicator Light is always bright or flashing (high-end H-type)
Parameter SettingAction voltage setting, master-slave setting (high-end H-type)
Environmental ConditionsField-of-UseIndoor, free from direct sunlight, dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water, or salt
Ambient Temperature-10℃ - +45℃, excellent ventilation
Ambient Humidity<90%RH, No condensation
Elevation Above Sea Level<1000m (over 1000m, 1% decrease per 100m)
Vibration<0.5g
Storage Temperature-20℃ - +60℃
Cooling MethodForced air cooling
Class of ProtectionIP00

Applications

Widely used in CNC machine tools,elevators,centrifuges, cranes,mine hoist and other machinery of variable frequency speed field, applicable to a variety of motor energy braking occasions.

Download

undefined

undefined

Brake Unit

Product Model:

Brake Unit uses advanced power technology and high- performance MCU controller and with a New generation of IFBT power devices combined with research and production of high performance brake products The product releases the electric energy generated by the motor during the braking process through the power resistance (braking resistance) to generate enough braking torque to keep the frequency converter and other equipment in normal operation.

Keywords:

Download File:


Online Message

Ready to grow your business? Your next great business opportunity starts with an inquiry.


Security verification
Send Inquiry Now