◪Many features are the same as E5-P, and strong starting torque and complete protection functions
◪Sleep Control about small pump: let system in sleep state to control , and control the special small pump in sleep state
◪Alternate to work on time: avoid the rust of the pump and prevent same pump to nonstop Work
◪Automatic switch: when the water supply changes in large flow, the pump can be automatically switched to control
◪Over-voltage and under-voltage control: real-time monitoring of the system, alarm of over-pressure and under-pressure, optional stop processing
◪Multi-period pressure control: under change of daily water demand, smooth water supply with multiple designated pressure in stages, and save electricity and water everyday
◪Designated day and pressure to supply water under constant pressure: specific pressure can be set when the pressure changes significantly over the weekend or on a fixed day, and it will be finished with weekly Cycle
◪Smooth switch: users can adjust according to the site to avoid current shock and hydraulic shock
Product Overview
E5-PA series is a new constant pressure water supply inverter launched by V&T.
E5-PA inverter, combined with the multi-pump control expansion card, can realize the multi-pump constant pressure water supply in turn with circulating; Built-in PID control--the current water pressure is detected by the pressure sensor, and according to the change of water pressure, 4 pumps are automatically switched to water supply at constant pressure under same power; At the same time, it can realize overpressure alarm, underpressure alarm, multi-time water supply at constant pressure, water supply at pressure constant with designated pressure and designated date, sleep control, change pump on time and so on.
◪E5−PA−4T□□□X 3 Phase 400V Variable/Light Load Application
Power(kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | ||||||||||||||||||||||||||||||
Motor(kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | ||||||||||||||||||||||||||||||
Output | Voltage(V) | 3 phase 0~Rated Voltage | |||||||||||||||||||||||||||||||||||||||||||
Rated Current(A) | 3.3 | 5.0 | 7.5 | 11 | 17 | 22 | 30 | 38 | 45 | 57 | 75 | 91 | 112 | 142 | 176 | ||||||||||||||||||||||||||||||
Overload capacity | 120% 1min, 160% 0.5 second,interval: 10 minutes (inverse time lag feature) | ||||||||||||||||||||||||||||||||||||||||||||
Input | Voltage/ frequency | 3 phase 380V~480V;50Hz/60Hz | |||||||||||||||||||||||||||||||||||||||||||
Allowable voltage range | 323V~528V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% | ||||||||||||||||||||||||||||||||||||||||||||
Rated Current(A) | 3.6 | 5.5 | 8.3 | 12 | 19 | 25 | 33 | 40 | 50 | 62 | 80 | 100 | 121 | 156 | 194 | ||||||||||||||||||||||||||||||
Braking unit | Built-in as standard | External braking unit needed | |||||||||||||||||||||||||||||||||||||||||||
IP | IP20 | ||||||||||||||||||||||||||||||||||||||||||||
Cooling mode | Natural air cooling | Forced air cooling | |||||||||||||||||||||||||||||||||||||||||||
Power(kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 |
| ||||||||||||||||||||||||||||||
Motor(kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 |
| ||||||||||||||||||||||||||||||
Output | Voltage(V) | 3 phase 0~Rated Voltage | |||||||||||||||||||||||||||||||||||||||||||
Rated Current(A) | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | 950 |
| ||||||||||||||||||||||||||||||
Overload capacity | 120% 1min, 160% 0.5 second,interval: 10 minutes (inverse time lag feature) | ||||||||||||||||||||||||||||||||||||||||||||
Input | Voltage/ frequency | 3 phase 380V~480V;50Hz/60Hz | |||||||||||||||||||||||||||||||||||||||||||
Allowable voltage range | 323V~528V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% | ||||||||||||||||||||||||||||||||||||||||||||
Rated Current(A) | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670 | 755* | 840* | 920* |
| ||||||||||||||||||||||||||||||
Braking unit | External braking unit needed | ||||||||||||||||||||||||||||||||||||||||||||
IP | IP20 | ||||||||||||||||||||||||||||||||||||||||||||
Cooling mode | Forced air cooling |
E5-PA-4T110X and higher power grade is standard external DC reactor
◪Product appearance, installation dimensions, approximate weight
E5−PA−4T11X and lower power grade
E5−PA−4T15X and higher power grade
◪Product appearance, installation dimensions, approximate weight
Voltage | Model | Appearance, Installation Dimensions(mm) | Weight (kg) | |||||||
W | H | D | W1 | H1 | D1 | T1 | Hole d | |||
400V | E5−PA−4T1.5X | 118 | 190 | 155 | 105 | 173 | 40.8 | 3 | 5.5 | 1.5 |
E5−PA−4T2.2X | 118 | 190 | 175 | 105 | 173 | 60.5 | 4 | 5.5 | 2.6 | |
E5−PA−4T3.7X | ||||||||||
E5−PA−4T5.5X | ||||||||||
E5−PA−4T7.5X | 155 | 249 | 185 | 136 | 232 | 69 | 8 | 5.5 | 3 | |
E5−PA−4T11X | ||||||||||
E5−PA−4T15X | 210 | 337 | 200 | 150 | 324 | 107.5 | 2.5 | 7 | 8.5 | |
E5−PA−4T18.5X | ||||||||||
E5−PA−4T22X | 285 | 440 | 220 | 200 | 425 | 107.5 | 2.5 | 7 | 17 | |
E5−PA−4T30X | ||||||||||
E5−PA−4T37X | ||||||||||
E5−PA−4T45X | 315 | 575 | 227 | 220 | 553 | 123.5 | 2.5 | 10 | 25 | |
E5−PA−4T55X | ||||||||||
E5−PA−4T75X | 400 | 615 | 265 | 270 | 590 | 123.5 | 3.0 | 10 | 35 | |
E5−PA−4T90X | ||||||||||
E5−PA−4T110X | 465 | 745 | 325 | 343 | 715 | 156 | 3.0 | 12 | 55 | |
E5−PA−4T132X | ||||||||||
E5−PA−4T160X | 540 | 890 | 385 | 370 | 855 | 205.5 | 4.0 | 14 | 85 | |
E5−PA−4T185X | ||||||||||
E5−PA−4T200X | ||||||||||
E5−PA−4T220X | ||||||||||
E5−PA−4T250X | 700 | 1010 | 385 | 520 | 977 | 210 | 4.0 | 14 | 125 | |
E5−PA−4T280X | ||||||||||
E5−PA−4T315X | ||||||||||
E5−PA−4T355X | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 | |
E5−PA−4T400X | ||||||||||
E5−PA−4T450X | ||||||||||
E5−PA−4T500X | ||||||||||
E5−PA−4T560X |