Representative Industry
Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal
Products Equipment, Centrifuges and High-end applications requiring closed-loop vector or torque control.
For examples, ShenYang Machine Tool Group, World Machine Group, King Long Motor Group, ShanXi Transformer Factory.
◪Open - loop vector, Closed - loop vector, Open - loop torque, Closed - loop torque control.
◪Inverter operates stably without tripping under any acceleration and deceleration time and any impact load.
◪Real torque control is realized through the independent current loop control, and online switching between torque control and speed control is supported.
◪Independent input and output port of high speed pulse, which can realize high speed pulse cascade function.
◪Accurate speed identification and rotor flux orientation, the torque can also respond quickly and operate stably when a load of 0.25hz breaks.
◪High-precision current detection and protection, high-precision hall to detect output current, realization of fast real-time control and protection of software and hardware, and assurance of performance and reliability of the whole machine.
V6-H series overview
V6-H series is a high performance vector control and torque control inverter.The product adopts open-loop vector control technology and torque control technology which are synchronized with the current international advanced technology, and it has the same excellent control performance with the international high-end frequency converter. At the same time, it is combined with the application characteristics of China, and it further strengthened the reliability and environmental adaptability of the product, as well as the customized and professional design, which greatly meet the needs of various transmission applications.
◪V6−H−4T□□□G Three−phase 400V Constant torque/heavy−duty application
Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Motor power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | ||||||||||||||
Rated current (A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Ratedvoltage/frequency | Three−phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||
Rated current (A) | 2.8 | 4.2 | 6.1 | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 | |
Braking unit | Built−in as standard | Built−in as option | ||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Natural−cooling | Forced air cooling | ||||||||||||||
Power (kW) | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 |
| |
Motor power (kW) | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 |
| |
Output | Voltage (V) | Three−phase 0 to rated input voltage | ||||||||||||||
Rated current (A) | 176 | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 |
| |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||
Input | Rated voltage/frequency | Three−phase 380V/480V; 50Hz/60Hz | ||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||
Rated current (A) | 160* | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* |
| |
Braking unit | External braking unit needed | |||||||||||||||
Protection class | IP20 | |||||||||||||||
Cooling mode | Forced air cooling |
※V6−H−4T90G and higher products are equipped with external DC reactor as standard.
◪V6−H−4T□□□L Three−phase 400V Variable torque/light−duty application
Power (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | ||
Motor power (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | ||
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||||
Rated current (A) | 3.3 | 5.0 | 7.5 | 11 | 17 | 22 | 30 | 37 | 44 | 56 | 72 | 91 | 110 | 142 | 176 | ||
Overload capacity | 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||||||||||||||
Input | Ratedvoltage/frequency | Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||||
Allowable voltage fluctuation range | 323V ~ 528V; Voltage imbalance: ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||||
Rated current (A) | 3.6 | 5.5 | 8.3 | 12 | 19 | 25 | 33 | 40 | 50 | 62 | 80 | 100 | 121 | 156 | 194 | ||
Braking unit | Built−in as standard | Built−in as option | |||||||||||||||
Protection class | IP20 | ||||||||||||||||
Cooling mode | Natual -cooling | Forced air cooling | |||||||||||||||
Power (kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 |
| ||
Motor power (kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 |
| ||
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||||
Rated current (A) | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | 950 |
| ||
Overload capacity | 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||||||||||||||
Input | Rated voltage/ frequency | Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||||
Allowable voltage | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||||
Rated current (A) | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* | 920* |
| ||
Braking unit | External braking unit needed | ||||||||||||||||
Protection class | IP20 | ||||||||||||||||
Cooling mode | Forced air cooling |
※V6−H−4T110L and higher power products are equipped with external DC reactor as standard.
◪V6−H−2T□□□G Three−phase 400V Constant torque/heavy−duty application
Power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | |
Motor power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||
Rated current (A) | 3 | 5 | 7.5 | 10 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||
Input | Rated voltage/frequency | Three−phase or single−phase 200V~240V; 50Hz/60Hz | |||
Allowable voltagerange | 180V ~ 260V; Voltage imbalance≤3%; allowable frequency fluctuation: ±5% | ||||
Rated current (A) | 3.8 | 5.5 | 8.3 | 12 | |
Braking unit | Built−in as standard | ||||
Protection class | IP20 | ||||
Cooling mode | Natural−cooling | Forced air cooling |
◪Product appearance, installation dimensions, approximate weight
V6−H−2T0.4G~V6−H−2T2.2G、V6−H−4T7.5G/11L And lower these power grade
V6−H−4T11G/15L And higher these power grade
◪Product appearance, installation dimensions, approximate weight
Voltage | Model | Appearance, installation dimension(mm) | weight(kg) | |||||||
W | H | D | W1 | H1 | D1 | T1 | Hole d | |||
200V | V6−H−2T0.4G | 118 | 190 | 155 | 105 | 173 | 40.8 | 3 | 5.5 | 1.5 |
V6−H−2T0.75G | 175 | 60.5 | 4 | 2.2 | ||||||
V6−H−2T1.5G | 155 | 40.8 | 3 | 1.5 | ||||||
V6−H−2T2.2G | 175 | 60.5 | 4 | 2.2 | ||||||
400V | V6−H−4T0.75G/1.5L | 118 | 190 | 155 | 105 | 173 | 40.8 | 3 | 5.5 | 1.5 |
V6−H−4T1.5G/2.2L | 118 | 190 | 175 | 105 | 173 | 60.5 | 4 | 5.5 | 2.6 | |
V6−H−4T2.2G/3.7L | ||||||||||
V6−H−4T3.7G/5.5L | ||||||||||
V6−H−4T5.5G/7.5L | 155 | 249 | 185 | 136 | 232 | 69 | 8 | 5.5 | 4.5 | |
V6−H−4T7.5G/11L | ||||||||||
V6−H−4T11G/15L | 210 | 337 | 200 | 150 | 324 | 88 | 2 | 7 | 8.5 | |
V6−H−4T15G/18.5L | ||||||||||
V6−H−4T18.5G/22L | 289 | 440 | 215 | 200 | 425 | 88 | 2.5 | 7 | 17 | |
V6−H−4T22G/30L | ||||||||||
V6−H−4T30G/37L | ||||||||||
V6−H−4T37G/45L | 319 | 575 | 212 | 220 | 553 | 90.5 | 2.5 | 10 | 25 | |
V6−H−4T45G/55L | ||||||||||
V6−H−4T55G/75L | 404 | 615 | 255 | 270 | 590 | 86.5 | 3.0 | 10 | 35 | |
V6−H−4T75G/90L | ||||||||||
V6−H−4T90G | 465 | 745 | 325 | 343 | 715 | 151.5 | 3.0 | 12 | 55 | |
V6−H−4T110G | ||||||||||
V6−H−4T132G | 540 | 890 | 385 | 370 | 855 | 205.5 | 4.0 | 14 | 85 | |
V6−H−4T160G | ||||||||||
V6−H−4T185G | ||||||||||
V6−H−4T200G | ||||||||||
V6−H−4T220G | 700 | 1010 | 385 | 520 | 977 | 210 | 4.0 | 14 | 125 | |
V6−H−4T250G | ||||||||||
V6−H−4T280G | ||||||||||
V6−H−4T315G | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 | |
V6−H−4T355G | ||||||||||
400V | V6−H−4T400G | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 |
V6−H−4T450G | ||||||||||
V6−H−4T500G |
Copyright © 2019 Shenzhen V&T Technologies Co., Ltd. | All Rights Reserved
Nice to meet you!We will reply to your message as soon as we receive it.