Representative Industry
Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal
Products Equipment, Centrifuges and High-end applications requiring closed-loop vector or torque control.
n Multiple System Loop Control Modes
u Position loop
u Speed loop
u Torque loop
n Speed Command Selection Is Flexible and Convenient
u Modbus communication
u Analog given
u Multi-segment speed given
u Terminal UP/DN given
u Process PID given
u Simple PLC speed given
n Multiple Running Instructions Setting Methods
u Modbus communication
u Keyboard given
u Terminal given
n LED Operation Panel / LCD Liquid Crystal Operation Panel Are Optional
u Modbus communication, standard network port connection are adopted in LED operation panel / LCD liquid crystal operation panel
u The layout of the button accords with ergonomic principle
u One-button parameter entry and exit,easy to operate
u Parameter copy function, remote control box function (up to 500m) can be realized by the operation panel
u The operation panel has a password lock function to prevent non-professionals from changing parameters by mistake
n Upper Computer Communication
u Provide 485 communication interface, the communication protocol is Modbus
u Parameter upload and download functions can be implemented
V9-H series overview
The V9−H Series General Purpose Inverter is a high-performance vector control and torque-controlled inverter. Vector control techniques and torque control techniques are employed. It not only has excellent control performance, but also combines the application characteristics of China, further strengthening the reliability of the product, environmental adaptability and customized and industrialized design, which can better meet the needs of various transmission applications.
The V9−H product voltage range covers 200V, 400V, 690V, and 1140V. The product power range covers 0.4kW to 3MW, which can meet the application needs of various high, medium and low end markets.
◪V9−H−4T□□□G Three−phase 400V Constant torque/heavy−duty application
Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
Motor power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||||
Rated current (A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | 176 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||||||||||||||
Input | Ratedvoltage/frequency | Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||||
Rated current (A) | 2.8 | 4.2 | 6.1 | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 | 194 | |
Braking unit | Built−in as standard | Built−in as option | |||||||||||||||
Protection class | IP20 | ||||||||||||||||
Cooling mode | Self −cooling | Forced cooling | |||||||||||||||
Power (kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 |
| |
Motor power (kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 |
| |
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||||||||||||||
Rated current (A) | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | 950 | 1100 |
| |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||||||||||||||
Input | Rated voltage/frequency | Three−phase 380V/480V; 50Hz/60Hz | |||||||||||||||
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||||||||||||||
Rated current (A) | 231 | 232 | 282 | 326 | 352 | 385 | 437 | 491 | 580 | 624 | 670 | 755 | 840 | 920 | 1050 |
| |
Braking unit | External braking unit needed | ||||||||||||||||
Protection class | IP20 | ||||||||||||||||
Cooling mode | Forced cooling |
※ 0.75kW~15kW:no built-in DC reactor
18.5kW~110kW:optional DC reactor
132kW~160kW:standard built-in DC reactor
185kW~500kW:standard external DC reactor
560kW~630kW:standard built-in AC input reactor
l The inverters with higher power level can be customized
l 220V, 690V, 1140V and other voltage level inverters can be customized
◪V9−H−4T□□□L Three−phase 400V Variable torque/light−duty application
Power (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | ||
Motor power (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | ||
Output | Voltage (V) | Three−phase 0 to rated input voltage | ||||||||||||||||
Rated current (A) | 3.3 | 5.0 | 7.5 | 11 | 17 | 22 | 30 | 37 | 44 | 56 | 72 | 91 | 110 | 144 | 180 | 216 | ||
Overload capacity | 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||||
Input | Ratedvoltage/frequency | Three−phase 380V/480V; 50Hz/60Hz | ||||||||||||||||
Allowable voltage fluctuation range | 323V ~ 528V; Voltage imbalance: ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||||
Rated current (A) | 3.6 | 5.5 | 8.3 | 12 | 19 | 25 | 32 | 39 | 50 | 61 | 77 | 100 | 121 | 158 | 198 | 238 | ||
Braking unit | Built−in as standard | Built−in as option | ||||||||||||||||
Protection class | IP20 | |||||||||||||||||
Cooling mode | Natual -cooling | Forced cooling | ||||||||||||||||
Power (kW) | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 | 710 | |||
Motor power (kW) | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | 630 | 710 | |||
Output | Voltage (V) | Three−phase 0 to rated input voltage | ||||||||||||||||
Rated current (A) | 242 | 325 | 365 | 405 | 440 | 495 | 547 | 610 | 695 | 770 | 866 | 950 | 1100 | 1200 | 1300 | |||
Overload capacity | 120% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||||||||
Input | Rated voltage/ frequency | Three−phase 380V/480V; 50Hz/60Hz | ||||||||||||||||
Allowable voltage | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||||||||
Rated current (A) | 266 | 282 | 326 | 352 | 385 | 437 | 491 | 580 | 670 | 755 | 840 | 920 | 1050 | 1150 | 1250 | |||
Braking unit | External braking unit needed | |||||||||||||||||
Protection class | IP20 | |||||||||||||||||
Cooling mode | Forced cooling |
※V6−H−4T110L and higher power products are equipped with external DC reactor as standard.
◪V6−H−2T□□□G Three−phase 400V Constant torque/heavy−duty application
Power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | |
Motor power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage | |||
Rated current (A) | 3 | 5 | 7.5 | 10 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | ||||
Input | Rated voltage/frequency | Three−phase or single−phase 200V~240V; 50Hz/60Hz | |||
Allowable voltagerange | 180V ~ 260V; Voltage imbalance≤3%; allowable frequency fluctuation: ±5% | ||||
Rated current (A) | 3.8 | 5.5 | 8.3 | 12 | |
Braking unit | Built−in as standard | ||||
Protection class | IP20 | ||||
Cooling mode | Natural−cooling | Forced air cooling |
◪Product appearance, installation dimensions, approximate weight
V9−H−4T7.5G/11L And lower these power grade
V9−H−4T11G/15L And higher these power grade
◪Product appearance, installation dimensions, approximate weight
Voltage | Model | Appearance, installation dimension(mm) | weight(kg) | ||||||
W | H | D | W1 | H1 | T1 | Hole d | |||
400V | V9−H−4T0.75G/1.5L | 118 | 190 | 155 | 105 | 173 | 3 | 5.5 | 1.5 |
V9−H−4T1.5G/2.2L | 118 | 190 | 175 | 105 | 173 | 4 | 5.5 | 2.6 | |
V9−H−4T2.2G/3.7L | |||||||||
V9−H−4T3.7G/5.5L | |||||||||
V9−H−4T5.5G/7.5L | 155 | 249 | 185 | 136 | 232 | 8 | 5.5 | 3 | |
V9−H−4T7.5G/11L | |||||||||
V9−H−4T11G/15L | 198 | 299 | 190 | 160 | 283 | 1.2 | 6 | 8 | |
V9−H−4T15G/18.5L | |||||||||
V9−H−4T18.5G/22L | 223 | 348 | 208 | 195 | 335 | 1.5 | 6 | 10 | |
V9−H−4T22G/30L | |||||||||
V9−H−4T30G/37L | 264 | 430 | 235 | 230 | 418 | 1.5 | 7 | 18 | |
V9−H−4T37G/45L | |||||||||
V9−H−4T45G/55L | 305 | 545 | 270 | 245 | 523 | 1.5 | 10 | 35 | |
V9−H−4T55G/75L | |||||||||
V9−H−4T75G/90L | 338 | 580 | 310 | 270 | 560 | 1.5 | 10 | 52 | |
V9−H−4T90G/110L | |||||||||
V9−H−4T110G/132L | |||||||||
V9−H−4T132G/160L | 400 | 917 | 323 | 320 | 890 | 3.0 | 12 | 75 | |
V9−H−4T160G/185L | |||||||||
V9−H−4T185G/200L | 540 | 890 | 385 | 370 | 855 | 4.0 | 14 | 85 | |
V9−H−4T200G/220L | |||||||||
V9−H−4T220G/250L | 540 | 890 | 385 | 370 | 855 | 4.0 | 14 | 85 | |
V9−H−4T250G/280L | 700 | 1010 | 385 | 520 | 977 | 4.0 | 14 | 125 | |
V9−H−4T280G/315L | |||||||||
V9−H−4T315G/355L | 700 | 1010 | 418.5 | 520 | 1300 | 4.0 | 14 | 215 | |
V9−H−4T355G/400L | 810 | 1358 | 425 | 520 | 1300 | 4.0 | 14 | 215 | |
400V | V9−H−4T400G/450L | 810 | 1358 | 425 | 520 | 1300 | 4.0 | 14 | 215 |
V9−H−4T450G/500L | |||||||||
V9−H−4T500G/560L |
Copyright © 2019 Shenzhen V&T Technologies Co., Ltd. | All Rights Reserved
Nice to meet you!We will reply to your message as soon as we receive it.