Company Advantages1. A series of manufacturing steps are covered in V&T Technologies
variable frequency drive. It has to be stamped, cut, coated, painted, dried, and assembled by skillful mechanical technicians. The product features higher energy-saving and less reactive current
2. V6 series inverter is often praised by it's perfect service. With speed adjustability, it features better power optimization
3. The product is able to manage well its heat. It has a heat dissipation substrate that effectively acts as an essential role in cooling. The product has many input and output interfaces
4. The product features a reliable operation. It is mainly controlled through computers. Unless maintenance is needed, it can go on without any break. The excellent current and voltage control technology allows it to operates stably
5. The product features the desired electromagnetic compatibility. It doesn't emit a large amount of electromagnetic interference and it continues to function as intended in the presence of several electromagnetic phenomena. The product has the advantages of deep weak magnetic control
Representative Industry
Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal
Products Equipment, Centrifuges and High-end applications requiring closed-loop vector or torque control.
For examples, ShenYang Machine Tool Group, World Machine Group, King Long Motor Group, ShanXi Transformer Factory.
◪Open - loop vector, Closed - loop vector, Open - loop torque, Closed - loop torque control.
◪Inverter operates stably without tripping under any acceleration and deceleration time and any impact load.
◪Real torque control is realized through the independent current loop control, and online switching between torque control and speed control is supported.
◪Independent input and output port of high speed pulse, which can realize high speed pulse cascade function.
◪Accurate speed identification and rotor flux orientation, the torque can also respond quickly and operate stably when a load of 0.25hz breaks.
◪High-precision current detection and protection, high-precision hall to detect output current, realization of fast real-time control and protection of software and hardware, and assurance of performance and reliability of the whole machine.
V6-H series overview
V6-H series is a high performance vector control and torque control inverter.The product adopts open-loop vector control technology and torque control technology which are synchronized with the current international advanced technology, and it has the same excellent control performance with the international high-end frequency converter. At the same time, it is combined with the application characteristics of China, and it further strengthened the reliability and environmental adaptability of the product, as well as the customized and professional design, which greatly meet the needs of various transmission applications.

◪V6−H−4T□□□G Three−phase 400V Constant torque/heavy−duty application
Power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 |
Motor power (kW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 |
Output | Voltage (V) | Three−phase 0 to rated input voltage |
Rated current (A) | 2.5 | 3.8 | 5.5 | 9 | 13 | 17 | 24 | 30 | 39 | 45 | 60 | 75 | 91 | 112 | 150 |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input | Ratedvoltage/frequency | Three−phase 380V/480V; 50Hz/60Hz |
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% |
Rated current (A) | 2.8 | 4.2 | 6.1 | 10 | 15 | 19 | 26 | 33 | 43 | 50 | 66 | 83 | 100 | 123 | 165 |
Braking unit | Built−in as standard | Built−in as option |
Protection class | IP20 |
Cooling mode | Natural−cooling | Forced air cooling |
Power (kW) | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | |
Motor power (kW) | 90 | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage |
Rated current (A) | 176 | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input | Rated voltage/frequency | Three−phase 380V/480V; 50Hz/60Hz |
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% |
Rated current (A) | 160* | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* | |
Braking unit | External braking unit needed |
Protection class | IP20 |
Cooling mode | Forced air cooling |
※V6−H−4T90G and higher products are equipped with external DC reactor as standard.
◪V6−H−4T□□□L Three−phase 400V Variable torque/light−duty application
Power (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 |
Motor power (kW) | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 |
Output | Voltage (V) | Three−phase 0 to rated input voltage |
Rated current (A) | 3.3 | 5.0 | 7.5 | 11 | 17 | 22 | 30 | 37 | 44 | 56 | 72 | 91 | 110 | 142 | 176 |
Overload capacity | 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input | Ratedvoltage/frequency | Three−phase 380V/480V; 50Hz/60Hz |
Allowable voltage fluctuation range | 323V ~ 528V; Voltage imbalance: ≤3%; allowable frequency fluctuation: ±5% |
Rated current (A) | 3.6 | 5.5 | 8.3 | 12 | 19 | 25 | 33 | 40 | 50 | 62 | 80 | 100 | 121 | 156 | 194 |
Braking unit | Built−in as standard | Built−in as option |
Protection class | IP20 |
Cooling mode | Natual -cooling | Forced air cooling |
Power (kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | |
Motor power (kW) | 110 | 132 | 160 | 185 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | |
Output | Voltage (V) | Three−phase 0 to rated input voltage |
Rated current (A) | 210 | 253 | 304 | 350 | 380 | 426 | 470 | 520 | 600 | 650 | 690 | 775 | 860 | 950 | |
Overload capacity | 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input | Rated voltage/ frequency | Three−phase 380V/480V; 50Hz/60Hz |
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% |
Rated current (A) | 196* | 232* | 282* | 326* | 352* | 385* | 437* | 491* | 580* | 624* | 670* | 755* | 840* | 920* | |
Braking unit | External braking unit needed |
Protection class | IP20 |
Cooling mode | Forced air cooling |
※V6−H−4T110L and higher power products are equipped with external DC reactor as standard.
◪V6−H−2T□□□G Three−phase 400V Constant torque/heavy−duty application
Power (kW) | 0.4 | 0.75 | 1.5 | 2.2 |
Motor power (kW) | 0.4 | 0.75 | 1.5 | 2.2 |
Output | Voltage (V) | Three−phase 0 to rated input voltage |
Rated current (A) | 3 | 5 | 7.5 | 10 |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) |
Input | Rated voltage/frequency | Three−phase or single−phase 200V~240V; 50Hz/60Hz |
Allowable voltagerange | 180V ~ 260V; Voltage imbalance≤3%; allowable frequency fluctuation: ±5% |
Rated current (A) | 3.8 | 5.5 | 8.3 | 12 |
Braking unit | Built−in as standard |
Protection class | IP20 |
Cooling mode | Natural−cooling | Forced air cooling |
◪Product appearance, installation dimensions, approximate weight
V6−H−2T0.4G~V6−H−2T2.2G、V6−H−4T7.5G/11L And lower these power grade
V6−H−4T11G/15L And higher these power grade
◪Product appearance, installation dimensions, approximate weight
Voltage | Model | Appearance, installation dimension(mm) | weight(kg) |
W | H | D | W1 | H1 | D1 | T1 | Hole d |
200V | V6−H−2T0.4G | 118 | 190 | 155 | 105 | 173 | 40.8 | 3 | 5.5 | 1.5 |
V6−H−2T0.75G | 175 | 60.5 | 4 | 2.2 |
V6−H−2T1.5G | 155 | 40.8 | 3 | 1.5 |
V6−H−2T2.2G | 175 | 60.5 | 4 | 2.2 |
400V | V6−H−4T0.75G/1.5L | 118 | 190 | 155 | 105 | 173 | 40.8 | 3 | 5.5 | 1.5 |
V6−H−4T1.5G/2.2L | 118 | 190 | 175 | 105 | 173 | 60.5 | 4 | 5.5 | 2.6 |
V6−H−4T2.2G/3.7L |
V6−H−4T3.7G/5.5L |
V6−H−4T5.5G/7.5L | 155 | 249 | 185 | 136 | 232 | 69 | 8 | 5.5 | 4.5 |
V6−H−4T7.5G/11L |
V6−H−4T11G/15L | 210 | 337 | 200 | 150 | 324 | 88 | 2 | 7 | 8.5 |
V6−H−4T15G/18.5L |
V6−H−4T18.5G/22L | 289 | 440 | 215 | 200 | 425 | 88 | 2.5 | 7 | 17 |
V6−H−4T22G/30L |
V6−H−4T30G/37L |
V6−H−4T37G/45L | 319 | 575 | 212 | 220 | 553 | 90.5 | 2.5 | 10 | 25 |
V6−H−4T45G/55L |
V6−H−4T55G/75L | 404 | 615 | 255 | 270 | 590 | 86.5 | 3.0 | 10 | 35 |
V6−H−4T75G/90L |
V6−H−4T90G
V6−H−4T110L | 465 | 745 | 325 | 343 | 715 | 151.5 | 3.0 | 12 | 55 |
V6−H−4T110G
V6−H−4T132L |
V6−H−4T132G
V6−H−4T160L | 540 | 890 | 385 | 370 | 855 | 205.5 | 4.0 | 14 | 85 |
V6−H−4T160G
V6−H−4T185L |
V6−H−4T185G
V6−H−4T200L |
V6−H−4T200G
V6−H−4T220L |
V6−H−4T220G
V6−H−4T250L | 700 | 1010 | 385 | 520 | 977 | 210 | 4.0 | 14 | 125 |
V6−H−4T250G
V6−H−4T280L |
V6−H−4T280G
V6−H−4T315L |
V6−H−4T315G
V6−H−4T355L | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 |
V6−H−4T355G
V6−H−4T400L |
400V | V6−H−4T400G
V6−H−4T450L | 810 | 1358 | 425 | 520 | 1300 | 210 | 4.0 | 14 | 215 |
V6−H−4T450G
V6−H−4T500L |
V6−H−4T500G
V6−H−4T560L |